What This Error Means
F6 is not an official Nest thermostat error code. When people say “Nest F6”, they’re almost always seeing an F6 fault on the boiler, furnace, or heat pump that the Nest is controlling.
Translation: the Nest is asking for heat or cooling, but the equipment throws an F6 fault, locks itself out, and never actually runs.
Official Fix
Do the by-the-book stuff first. This is what the manuals want you to do.
- Confirm where F6 is showing.
Look at the Nest screen, then look at the boiler/furnace/air handler front panel. If F6 is on the equipment display, that’s the real source of the problem. The Nest is just the messenger. - Power-cycle the whole HVAC system.
Turn system OFF at the thermostat. Then kill power to the furnace/boiler/air handler at the breaker or fused switch. Wait 60 seconds. Turn power back on. Then set Nest to HEAT or COOL with a good 3–5°F (2–3°C) temperature difference and see if it runs without F6 coming back. - Check the obvious basics.
Make sure: breakers aren’t tripped, front panels and safety switches are fully closed, the furnace filter isn’t totally clogged, outdoor unit (heat pump/AC) isn’t buried in snow/leaves, and any visible isolation switches are ON. If something is clearly off or tripped, correct it and try again. - Read the equipment’s F6 definition.
Note the exact brand and model of your boiler/furnace/heat pump. F6 can mean slightly different things by brand (often ignition, fan, flow, or sensor failure), but in every case it means: “unit is faulted and locked out.” The official manual will usually say: reset the unit and, if F6 returns, call a qualified technician. - Do the safe reset the manual allows.
Many boilers and furnaces have a front reset button or require cycling power to clear a lockout. Follow the manufacturer’s reset instructions only. If F6 appears again after a proper reset, stop there. Repeated F6 means there’s a real hardware or safety issue the unit is protecting itself from. - Know when to stop.
If you smell gas, hear loud bangs, or the unit immediately goes back to F6 after every reset, don’t keep forcing it. That’s exactly the point where the manual says: call a qualified HVAC/boiler engineer.
If the equipment runs normally after a reset and F6 stays away, you’re done. If not, keep reading for the way a tech separates thermostat from equipment problems.
The Technician’s Trick
Here’s how a field tech quickly figures out if it’s the Nest side or the equipment side. Only do this if you’re comfortable around low-voltage wiring.
- Kill power and pull the Nest.
Turn HVAC power off at the breaker. Pop the Nest display off its wall base or disconnect the Heat Link (EU/UK). This removes the thermostat from the equation. - Bypass the thermostat with a jumper.
At the furnace/boiler control, or at the Heat Link, find the low‑voltage terminals the Nest uses for heat call (typically R and W, or the heating contacts on the Heat Link). With power off, connect them together using a short piece of wire. Restore power. If the unit now starts and runs without flashing F6, the equipment itself is basically OK. - Read the result.
If it runs fine on the jumper but not with the Nest: you’re looking at a Nest, Heat Link, or wiring issue. Check for loose thermostat wires, damaged cable, or a Nest that keeps rebooting from low power. Often the real fix is to add a proper C‑wire or a Nest Power Connector, or replace a flaky Heat Link.
If it still throws F6 or won’t start even with the jumper, the thermostat is innocent. You’ve got a straight equipment fault (fan, pump, sensor, ignition, or control board). That’s technician territory. - Optional: Quick fuse check.
Many furnaces have a little automotive-style 3A/5A fuse on the control board. With power OFF, you can visually check if it’s blown. If you swap it, use the exact same rating only. If it pops again, stop. There’s a short or other fault that needs a pro.
Is It Worth Fixing? (The Financial Verdict)
- ✅ Fix: Equipment under ~10–12 years old, F6 cleared by reset, fuse, wiring cleanup, or a cheap part (sensor, Nest Power Connector, or Heat Link) and the system otherwise runs strong.
- ⚠️ Debatable: System in the 12–15+ year range, F6 keeps coming back, or you’re being quoted for mid-priced parts like fans, pumps, or control boards. Ask for a full system health check before throwing money.
- ❌ Replace: Furnace/boiler/heat pump 15–20+ years old, multiple different fault codes in its history, or a repair quote that’s a big chunk of a new system price. Don’t sink big money into a zombie.
Parts You Might Need
- Nest Power Connector (C‑wire adapter) – Find Nest Power Connector on Amazon
- 18/5 thermostat wire – Find 18/5 thermostat wire on Amazon
- 24V 40VA HVAC transformer – Find 24V transformer on Amazon
- 3A/5A low-voltage blade fuse – Find low-voltage fuse on Amazon
- Nest Heat Link replacement (EU/UK setups) – Find Nest Heat Link on Amazon