What This Error Means
F8 on a Nest thermostat basically means: the thermostat is losing or not getting steady 24V power from your HVAC system.
Translation: the Nest tries to run your heat or AC, the voltage drops out, the thermostat glitches or reboots, so it throws an F8-style power fault.
Important note: Google’s official docs don’t list an F8 code for Nest. When people say “Nest F8”, it almost always comes down to a power/wiring issue like:
- No common (C) wire or bad C wire.
- Loose or miswired R/Rc wire.
- Weak or failing furnace/air-handler control board or transformer.
- Blown low-voltage fuse after a shorted thermostat wire.
What’s actually happening: the thermostat isn’t getting clean 24VAC, so it can’t stay powered reliably while calling for heating or cooling.
Official Fix
Here’s the “by the book” path that matches what Nest/Google support will walk you through.
1. Kill power before touching wires
- Turn off the furnace/air-handler breaker (and AC condenser breaker if separate).
- Wait at least 30 seconds. You want everything fully dead.
2. Check the thermostat wiring at the Nest base
- Pop the Nest display off the wall plate.
- Each wire should be:
- Stripped about 3/8″ (10 mm).
- Straight, copper clean and not corroded.
- Pushed fully in so the little tab stays down and doesn’t pop back up.
- Pay special attention to:
- R / Rc (power in).
- C (common) if you have one.
- Any wire you recently moved, added, or removed.
- If a wire is loose, frayed, or barely hanging on, re-strip and re-seat it.
3. Confirm you have a real C wire (or install one)
- If there is no wire in C at the Nest and at the furnace board, you’re running on “power stealing”. That’s where Nest issues like F8 and reboot loops come from.
- Official fix is either:
- Connect an existing spare conductor in the cable as a new C wire (C at furnace board to C at Nest).
- Or have a pro install a Nest Power Connector / C-wire kit at the furnace or air handler.
4. Check the furnace/air-handler control board
- With power still off, open the blower door panel.
- Find the low-voltage terminals marked R, C, W, Y, G.
- Make sure the thermostat wires are tight under the screws and not shorted or rubbed through on metal.
- Find the small 3–5 amp blade fuse on the board (looks like a car fuse). If it’s blown, replace with the same rating only.
5. Power back on and run Nest’s built-in tests
- Put the blower door back on so the safety switch is pressed.
- Turn breakers back on.
- Reattach the Nest display.
- On the Nest, go to Settings > Equipment > Continue > Test and run a heating and cooling test.
- If it passes and the thermostat stays on without rebooting, your F8-style issue is usually done.
6. When the official line is: call a pro
- If the fuse immediately blows again, or you never see 24V between R and C, the problem is deeper (shorted cable, bad board, weak transformer).
- At that point, Nest’s official answer is: get an HVAC technician to inspect wiring, transformer, and control board.
The Technician’s Trick
Here’s how a field tech shortcuts this instead of playing phone tag with support.
1. Charge the Nest so it quits rebooting
- Pop the Nest display off.
- Plug it into a phone charger (micro‑USB or USB‑C on the back, depending on model).
- Let it charge 20–30 minutes. This gives it enough battery to stay alive while you fix the power feed.
2. Check real voltage at the wall, not just at the board
- With breakers on and the Nest display removed, put a multimeter on the base terminals.
- Measure between R and C:
- You want roughly 24–30 VAC, solid and steady.
- If it’s under ~22 VAC or bouncing around, the issue is upstream (transformer, board, long run of wire).
- If you have good 24VAC at the board but not at the thermostat, the cable run is damaged. Techs often just pull a new thermostat cable and be done with it.
3. Fast DIY C-wire upgrade using a spare conductor
- If your thermostat cable has unused wires (often brown, blue, or black rolled up), use one.
- At the furnace board: land that spare wire on C.
- At the Nest base: land the same color wire on C.
- This one move alone fixes most Nest power-drop / F8-style issues.
4. External 24V transformer as a rescue (for advanced DIY)
- Buy a plug‑in 24VAC transformer (pre‑wired, two low‑voltage leads).
- Connect one lead to the Nest C terminal and the other to R (or tie into existing R/C correctly if you know what you’re doing).
- This feeds clean power to the Nest even if the furnace transformer is weak.
- If that instantly cures the problem, your furnace transformer or board is on its way out. Replace, don’t ignore.
- If you’re not fully comfortable with wiring diagrams, stop here and get a tech. Low voltage is safer, but you can still fry a board by guessing.
Is It Worth Fixing? (The Financial Verdict)
- ✅ Fix: HVAC system under ~12 years old, issue is just wiring, fuse, Nest Power Connector, or a thermostat cable pull. Cheap parts, quick labor.
- ⚠️ Debatable: Furnace/air-handler 13–18 years old and you’re already seeing random lockouts, weak blower, or repeated low‑voltage issues. Fix this round, but start budgeting for replacement.
- ❌ Replace: Control board and transformer are both failing, or the whole system is 18–20+ years old and needs major money in parts. Don’t sink big cash to chase an F8‑type power fault on a dying system.
Parts You Might Need
- Nest Power Connector (or similar C‑wire adapter) – Find Nest Power Connector on Amazon
- C‑wire / thermostat adapter kit – Find C‑wire adapter kit on Amazon
- 18/5 thermostat cable – Find 18/5 thermostat wire on Amazon
- 24VAC plug‑in transformer – Find 24VAC transformer on Amazon
- 3–5 amp low‑voltage fuse (for furnace board) – Find low‑voltage fuse on Amazon
- Digital multimeter – Find digital multimeter on Amazon
As an Amazon Associate we earn from qualifying purchases.