What This Error Means
F9 on a Nest thermostat means the Nest is seeing a furnace fault code 9 from your heating system. Bottom line: the furnace tried to start, hit a safety fault, and shut itself down.
What you feel: no heat, or heat that starts and quits after a few tries, while the Nest flashes a heating error. On the furnace itself, the little LED is usually blinking a matching code. Exact meaning of “code 9” varies by brand, but it always means a hard safety lockout, not just a software glitch in the Nest.
Official Fix
Here’s the textbook sequence Nest and the furnace manual expect you to follow:
- Flip the furnace/HVAC breaker off. Wait 30 seconds. Turn it back on. This clears a soft lockout.
- Check the furnace door. Make sure it’s fully seated and latched. A loose door opens the safety switch and can trigger F9.
- Pull the air filter. If it looks even moderately dirty, replace it. Restricted airflow overheats the heat exchanger and trips limit safeties.
- Walk the house and open all supply and return vents. Don’t run the system with half the vents closed; you’ll cook the furnace and see these faults again.
- Go to the furnace and look at the control board LED. Count the blink pattern or read the digital code and match it to the chart on the inside of the blower door.
- Use the Nest to call for heat again. If F9 returns, or the furnace keeps locking out, the official answer is: stop there and call a licensed HVAC technician.
The Technician’s Trick
Here’s the fast way techs separate a Nest problem from a furnace problem and clear a stubborn F9.
- Bypass the Nest.
Turn off furnace power at the breaker. Pull the blower door. On the control board, jumper R to W with a short insulated wire. Put the door back on so the safety switch is pressed, then restore power. If the furnace now runs a full heat cycle with no lockout, the furnace is basically fine and the issue is on the Nest side (wiring, power, or the stat itself). - If it still throws F9 / 9-blink with R–W jumped, hit the usual furnace culprits:
- Watch startup: inducer fan → pressure switch click → igniter glow → gas valve click → flame → blower. Note exactly where it fails. That points to the bad stage.
- Pull the flame sensor (small metal rod in the flame path), clean the rod gently with fine abrasive pad or steel wool, wipe it, and reinstall. A dirty sensor is a classic cause of repeated tries then lockout.
- If it’s a high-efficiency furnace (PVC intake/exhaust), pull and flush the condensate trap, clear the drain tube, and make sure all hoses are seated. Backed-up water will trip the pressure switch and lock the unit out.
- Inspect the small rubber hoses to the pressure switch. No kinks, cracks, or water in the line. Replace or re-route if anything looks sketchy.
- If the furnace passes the jumper test, clean up the Nest circuit:
- Kill power again. Pop the Nest off its base. Check the base and wires for burnt spots, corrosion, or a stray strand touching another terminal.
- Tighten all screws on R, W, and C at both the furnace board and the Nest base. Loose low-voltage screws cause voltage drops and random errors.
- Make sure a real C wire is connected to C at the furnace and to C at the Nest. Adapters and “power stealing” setups are way more likely to trip F-codes.
- With power on, meter between R and C at the furnace board. You want around 24 VAC. If it’s dead or very low, you’re looking at a bad 24V transformer or a blown low-voltage fuse on the board.
- As a sanity check, temporarily hook up a cheap non-smart thermostat. If that runs heat all day with no issues, the Nest is the weak link.
If anything inside that furnace cabinet makes you nervous, stop at the filter, vents, and breaker. Call a pro for the jumpers, gas, and electrical work.
Is It Worth Fixing? (The Financial Verdict)
- ✅ Fix: Furnace under ~15 years old, fault ends up being a dirty sensor, clogged drain, loose wire, or a Nest still under warranty.
- ⚠️ Debatable: Furnace in the 15–20 year range, repair quote in the $400–800 band, or you’ve had two or three lockout-related repairs in the last couple of seasons.
- ❌ Replace: Furnace 20+ years old, cracked heat exchanger or failed control board, or the repair plus a new smart thermostat creeps toward half the cost of a full system replacement.
Parts You Might Need
- Flame sensor (furnace) – common cause of lockouts right after ignition.
Find flame sensor on Amazon - Furnace pressure switch – if the error chart points to venting/draft or pressure problems.
Find furnace pressure switch on Amazon - Condensate trap / drain tubing – for high-efficiency units with standing water or drain issues.
Find condensate trap on Amazon - 24V furnace transformer – if you measure low or no 24 VAC feeding the thermostat circuit.
Find 24V furnace transformer on Amazon - Nest-compatible thermostat base / wall plate – if the Nest reboots when touched or the base looks damaged or burnt.
Find Nest thermostat base on Amazon