What This Error Means
F18 on a Nest thermostat basically means: your heating appliance (boiler or furnace) is sending its own fault code “F18” up to the Nest.
Plain English: Nest is calling for heat, but the boiler/furnace has locked itself out with fault F18, so it refuses to fire.
Plain English: Nest is calling for heat, but the boiler/furnace has locked itself out with fault F18, so it refuses to fire.
Official Fix
This one is mostly about the boiler/furnace, not the Nest. Here’s how the manuals expect you to handle it:
- 1. Figure out where F18 is really coming from.
- Check the Nest screen/app: if you see F18 plus a message about the boiler or equipment, Nest is just repeating the appliance’s error.
- Go to the boiler/furnace and look at its display or blinking LEDs. You’ll usually see the same F18 code there.
- Note the brand and model of the boiler/furnace – that decides what F18 actually means.
- 2. Use the boiler/furnace manual for the exact F18 meaning.
- Open the flap or front door (if it has one) and look for a fault-code chart. Many stick the list right inside.
- If you have the paper manual, look up “F18” in the fault / diagnostic section.
- Typical meanings for F18 across brands are things like temperature sensor fault, water flow fault, or internal safety lockout. In any case: it’s an internal boiler issue, not a Nest setting.
- 3. Do the safe, basic resets the manuals allow.
- Boiler with reset button: press and hold the reset as the manual says (often 3–5 seconds). Let it fully reboot.
- Wall switch / spur: turn the boiler/furnace off at its fused spur or switch, wait 30–60 seconds, turn it back on.
- Watch the display. If F18 stays gone and the flame icon shows, you’re good. Nest will clear itself once heat is restored.
- 4. Quick homeowner checks that usually are allowed.
- For combi / system boilers (radiators):
- Check the pressure gauge. If it’s under about 1.0 bar (cold), most manuals say top it up to 1.0–1.5 bar via the filling loop.
- Only top up if you know how and the manual says it’s ok. Don’t guess. If unsure: stop and call a heating engineer.
- Bleed very noisy or stone-cold radiators, then recheck pressure.
- For forced-air furnaces (ducted systems):
- Swap or clean the air filter. A choked filter can trigger all sorts of pressure and overheat faults.
- Make sure vents and combustion air intakes are not blocked by snow, leaves, or junk.
- For combi / system boilers (radiators):
- 5. Check Nest isn’t the weak link in the power chain.
- If the Nest keeps saying F18 but the boiler/furnace panel looks normal and fires fine, you may have a low-voltage / C‑wire issue rather than a real F18 fault.
- Make sure the Nest is:
- Seated properly on the base.
- Getting at least the minimum supply (typically 20–30V AC between R and C, or correctly wired to the Heat Link / zone controller).
- If you’re not confident with a multimeter or wiring, stop here and call a HVAC / boiler tech that knows Nest.
- 6. Know when you’re done and when you’re not.
- If a reset clears F18 and the boiler/furnace runs solid for a few heating cycles, you’re probably fine.
- If F18 comes back repeatedly or the appliance refuses to start, that’s an internal fault: temperature sensor, pump, board, gas train, or similar.
- At that point, the official line from both Nest and the boiler maker is: call a qualified heating engineer / HVAC tech. The thermostat cannot override an F18 lockout.
Bottom line: You don’t fix F18 inside the Nest menu. You fix it at the boiler/furnace, or you pay someone who does.
Is It Worth Fixing? (The Financial Verdict)
- ✅ Fix: F18 only appeared once, a simple reset or pressure top‑up cleared it, boiler/furnace is under ~10–12 years old, and everything now runs cleanly.
- ⚠️ Debatable: F18 keeps coming back a few times a season, the unit is 12–15 years old, or parts like sensors and pumps are starting to add up in repair bills.
- ❌ Replace: F18 is tied to major components (control board, heat exchanger, pump plus board), the unit is 15+ years old, or the quote is over ~40–50% of a modern, efficient replacement.
Parts You Might Need
- Nest Power Connector (C‑wire adapter) – if low voltage to the thermostat is part of the problem
Find Nest Power Connector on Amazon - 24VAC Transformer (for systems without a proper thermostat power feed)
Find 24VAC Transformer on Amazon - Boiler Temperature Sensor / NTC Probe (common cause of F‑codes on many boilers)
Find Boiler Temperature Sensor / NTC Probe on Amazon - Boiler / System Circulation Pump (if F18 on your model points to flow errors)
Find Circulation Pump on Amazon - Boiler Pressure Sensor / Flow Switch
Find Boiler Pressure Sensor / Flow Switch on Amazon - Replacement Nest Base / Backplate (if terminals are loose or damaged and causing power issues)
Find Nest Base / Backplate on Amazon